Anesthesia Workstation Practice 3800 Advanced

Safe, stable and efficient anesthesia management.

  • The characteristic breathing circuit is made of alloy, resistant to corrosion and can withstand repeated high temperature and high pressure sterilization.
  • Adjustable angle, easy to install, many user-friendly designs make maintenance easier.
  • The integrated heating system with a better thermal conductivity of alloy help prevent condensation and make patients feel more comfortable.
  • APL with fast release pressure, the upper pressure limit is accurately adjustable, avoiding repeated operations and improving anesthesia efficiency.
  • The Breathing Ciucuit has CO2 bypass function.
  • Practice 3800A has a minimum tidal volume of 10ml in volume control mode, in addition to possessing the PCV-VG and BIVENT ventilation mode, helping to achieve the precise low tidal volume required during lung protective ventilation.

Individualized PEEP titration tool

  • Stress index (SI) monitoring helps with Individualized PEEP titration. Through the guidance of the Static PV loop tool, the appropriate setting of PEEP value and tidal volume are realized

Digital Flowmeter with ECO-Optimizer

  • Digital Flowmeter makes fresh gas flow setting easier and more precise.
  • The ECO-Optimizer indicates the recommended fresh gas flow setting according to the setting value and the minimum O2 needed of the patient. It enables a safe Low Flow, and reduces the waste of anesthetic agents and medical gases

Minimized impact recruitment maneuver

  • Two types recruitment maneuvers: stepwise PEEP or sustained inflation.
  • Automate repetitive tasks used during lung ventilation procedures.
  • Enhanced monitoring and clinical tools
  • In addition to traditional monitoring parameters, special monitoring parameters, such as Driving Pressure(DP), are provided to guide clinicians in adjusting ventilation parameters.
  • Spirometry loops can be stored for future reference, a [lowing clinicians the ability to better understand changes in the patient’ s response to therapy.
  • Provide multiple of cardiopulmonary bypass modes (CBP) to assist in the implementation of cardiopulmonary bypass surgery.
  • Continuous trend information together with time discrete events are stored and shown in the table or chart.
  • Provides medical gas consumption calculations: including O2, NzO and Agent. And provide calculations of CO2 production.
BASE UNIT
Dimensions (H x W x D)

Trolley version (with breathing circuit)

1420mm×770mm×760mm
Weight :

Trolley (without vaporizer and backup cylinder) Top shelf load

 

135kg 25kg

Power input 100~240 VAC, 50/60 Hz
Batteries and Operation time with fully charged DC24V, 4.0AH, Min.120min
Operation temperature 10~+40ºC
Operation humidity ≤95%(non-condensing)
ANESTHESIA GAS SUPPLY MODULE
Gas supply O2, N2O, AIR 280kPa – 600kPa
Cylinder yokes Optional O2, N2O, AIR
Fresh gas flow indicator Electronically display and virtual fresh gas flow tubes
Range of fresh gas flow indicators O2, N2O (0~10.0 l/min), AIR (0~12.0 l/min)

O2flush 25~75 l/min

ACGO Optional
AGSS Optional
VAPORIZER
Agent Halothane, Enflurane, Isoflurane , Sevoflurane
Installation mode Selectatec® with interlock, optional standby vaporizer parking holder
Filling type Pour Fill, Key Fill, Quik-Fil
APL Range Spontaneous breathing (SP) -70cm H2O
CO2bypass Optional
VENTILATOR OPERATING SPECIFICATIONS
Ventilator Electronically controlled, pneumatically driven
Ventilation modes Manual/spontaneous

IPPV, PCV, PCV-VG, SIMV-VC, SIMV-PC, SIMV-VG, CPAP,BIVENT APRV

CONTROL INPUT RANGES
Breathing frequency (rate) 2~100bpm
PEEP OFF, 3~50cm H2O
Inspiration/expiration ratio (Ti:Te) 4:1~1:8
Tidal volume 20~1500ml(10~1500ml by Volume Control and SIMV modes)(5 to 1500 ml by PressureControl Vent Mode)
Inspiration pause OFF, 5%~60%
Inspiratory time 0.2~5.0 s
Inspiratory pressure 5~70cm H2O
Pressure support level 3~60cm H2O
Pmax 10~100 cm H2O
Trigger level 0.5~15 l/min
 

Monitoring

Continuous monitoring of inspiratory O2concentration, breathing frequency, tidal volume, minute volume, peak airway pressure, PEEP, mean or plateau pressure, CO2 concentration (optional), anesthetic gas concentration (optional) paramagnetic oxygen sensors (optional)
Compliance 0~100 mL/cm H2O
Control screen 15 inch; TFT color touch screen
Graph Display Waveform of P-t, F-t, V-t, CO2-t (option), Paw-V Loop, V-Flow Loop,P-F Loop
 

 

Alarm

MV high/low limit, FiO2high/low limit, Paw high/low limit, Power failure Breath Rate high limit

Subatmospheric pressure Sustained airway pressure

Apnea alarm, Alarm Silence(120s)

 

Basic service